Use este identificador para citar ou linkar para este item: https://repositorio.ufms.br/handle/123456789/562
Registro completo de metadados
Campo DCValorIdioma
dc.creatorZagatto, Alessandro Moura-
dc.creatorPapoti, Marcelo-
dc.creatorGobatto, Claudio Alexandre-
dc.date.accessioned2011-09-28T14:12:01Z-
dc.date.available2021-09-30T19:56:45Z-
dc.date.issued2009-
dc.identifier.citationZAGATTO, Alessandro Moura; PAPOTI, Marcelo; GOBATTO, Claudio Alexandre. Comparação entre ergômetros específico e convencionais na determinação da capacidade aeróbia de mesatenistas. Rev Bras Med Esporte, Niterói, v. 15, n. 3, jun. 2009 . Disponível em <http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1517-86922009000300008&lng=pt&nrm=iso>. acessos em 28 set. 2011. http://dx.doi.org/10.1590/S1517-86922009000300008.pt_BR
dc.identifier.urihttps://repositorio.ufms.br/handle/123456789/562-
dc.description.abstractO objetivo deste estudo foi verificar a necessidade de utilizar protocolo específico para avaliar a capacidade aeróbia de mesatenistas, comparando os testes aplicados em ergômetro específico com ergômetros convencionais. Para isso, nove mesatenistas foram os participantes do estudo (18,22 ± 2,33 anos; altura de 1,76 ± 0,09m; massa corporal de 67,36 ± 10,03kg; gordura corporal de 14,74 ± 6,69%; e índice de massa corporal (IMC) de 21,69 ± 2,71kg/m2). Foram aplicados os testes de lactato mínimo, realizados no ergômetro de braço (LACminbraço) e no cicloergômetro (LACminciclo) (ergômetros convencionais) e o teste de limiar anaeróbio em procedimento específico para o tênis de mesa (LAnespec) utilizando um lançador de bolas mecânico como ergômetro. Como procedimentos estatísticos foram utilizados o teste de análise de variância (ANOVA) one way e o teste de correlação produto-momento, com nível de significância de 5%. O LAnespec (48,11 ± 6,82 bolas.min-1) não foi significativamente correlacionado com a intensidade de LACminbraço (91,94 ± 11,51W) (r = 0,18; p = 0,72); e apresentou correlação negativa com a intensidade de LACminciclo (157,97 ± 12,51W) (r = - 0,80; p = 0,02). Desse modo, os resultados encontrados no estudo levam a concluir que existe necessidade do uso de protocolo específico para mensurar a capacidade aeróbia no tênis de mesa.pt_BR
dc.description.abstractABSTRACT - The aim of this study was to verify the necessity to use a specific protocol for evaluating the aerobic capacity in table tennis players, comparing the tests applied in conventional ergometers with test applied in specific ergometer. Nine table tennis players were participants in the study (18.22 ± 2.33 years; 1.76 ± 0.09 m of height; 67.36 ± 10.03 Kg of body mass; 14.74 ± 6.69 % of fat mass and 21.69 ± 2.71 Kg/m2 of body mass index). The participants performed lactate minimum tests in the arm ergometer and cycle ergometer; in addition to incremental test in specific ergometer for determination of the anaerobic threshold (AnTspec) through visual inspection. Statistical procedures used Analysis of Variance test (one-way ANOVA) and the Pearson correlation test, with level of significance of 5%. There was not significant correlation between the AnTspec (48.11 ± 6.82 shots.min-1) and the lactate minimum intensity obtained in arm ergometry (91.94 ± 11.51 W) (r=0.18; p=0.72). The lactate minimum intensity in cycle ergometer (157.97 ± 12.51 W) presented significant correlation with the AnTspec (r=-0.80; p=0.02), but a negative correlation was verified. Therefore, a specific protocol is needed for measuring the aerobic capacity in table tennis.pt_BR
dc.language.isoporpt_BR
dc.publisherRevista Brasileira de Medicina do Esportept_BR
dc.rightsAcesso Abertopt_BR
dc.subjectTênispt_BR
dc.subjectLimiar Anaeróbiopt_BR
dc.subjectEducação Física e Treinamentopt_BR
dc.subjectEsforço Físicopt_BR
dc.subjectTennispt_BR
dc.subjectAnaerobic Thresholdpt_BR
dc.subjectPhysical Education and Trainingpt_BR
dc.subjectPhysical Exertionpt_BR
dc.titleComparação entre ergômetros específico e convencionais na determinação da capacidade aeróbia de mesatenistaspt_BR
dc.title.alternativeComparison between specific and conventional ergometers in the aerobic capacity determination in table tennis playerspt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.doihttp://dx.doi.org/10.1590/S1517-86922009000300008-
Aparece nas coleções:CCHS - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Comparacao entre ergometros.pdf241,06 kBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.