Use este identificador para citar ou linkar para este item: https://repositorio.ufms.br/handle/123456789/2071
Registro completo de metadados
Campo DCValorIdioma
dc.creatorVieira, Juliana Maria Correia de Souza-
dc.date.accessioned2014-11-12T01:39:20Z-
dc.date.available2021-09-30T19:55:13Z-
dc.date.issued2013-
dc.identifier.urihttps://repositorio.ufms.br/handle/123456789/2071-
dc.description.abstractNeste trabalho de pesquisa avaliou-se através de testes o grau de microdureza de três cimentos resinosos: C1-VariolinkTM Veneer; C2-VariolinkTM II e; C3-RelyXTM ARC, fotopolimerizados através da interposição de barreiras confeccionadas com diferentes espessuras, utilizados em restaurações estéticas indiretas. Foram confeccionados vinte e quatro corpos-de-provas para cada marca de cimento, divididos em quatro grupos, segundo o tipo de barreira utilizada na interposição durante a sua fotopolimerização: SB-Sem barreira; B1 / Cerâmica e.max CAD/CAM 1,2mm; B2 / Cerâmica e.max CAD/CAM 1,0mm e; B3 / Cerâmica e.max CAD/CAM 0,7mm. A fotopolimerização foi realizada com luz LED Bluephase e as medidas foram realizadadas em dois períodos: imediato e sete dias após a polimerização, com um Microdurômetro HMV-2000 Shimadzu-Japan, sob cargas de 50gf durante 15s, cujos valores de microdureza foram obtidos em HV. Foram realizadas quatro leituras de cada ensaio, num total de 144 ensaios e, no final, foram calculadas as médias das mesmas. As médias restantes foram submetidas à ANOVA Fatorial e teste de Tukey HSD. Os valores médios das microdurezas sete dias após a polimerização foram superiores aos valores médios das microdurezas imediatamente após a polimerização. O cimento RelyX ARC teve os maiores valores de microdureza nos dois períodos de avaliação, com maior valor absoluto sem a interposição de barreira. O cimento Variolink Veneer obteve o menor valor da microdureza com a interposição das barreiras, com medição imediatamente após a polimerização. Os instantes de medição e o tipo de cimento interferiram nos valores das microdurezas, já a interposição de barreiras dos diversos materiais disponíveis durante a fotopolimerização de cimentos resinosos não interferiram significativamente nos valores das microdurezas dos mesmos.pt_BR
dc.description.abstractABSTRACT - This research evaluated testing the degree of hardness of three curing resin cements: C1 – VariolinkTM Veneer, C2 – VariolinkTM II; C3-RelyXTM ARC, light cured by interposing barriers made from different materials used in indirect restorations. Twenty-four test samples for each brand of cement was mode divided into four groups according to the type of barrier used in lodging during their curing: SB-No barrier; B1- e.max CAD/CAM ceramic 1,2mm; e.max CAD/CAM ceramic 1,0mm and B2-, B3 - e.max CAD/CAM ceramic 0,7mm. The polymerization was carried out with LED light bluephase and measurements were taken in two periods: immediate and seven days after polymerization with a microdurometer HMV-2000 Shimadzu-Japan under loads 50gf over 15s whose microhardness values were obtained in HV. Four readings were performed, a total of 144 trials and, in the end, we calculated the average of the same. The average remaining were subjected to factorial ANOVA and Tukey HSD test. The average values of microhardness seven days after polymerization were higher than the average of microhardness immediately after polymerization. The RelyXTM ARC showed higher values of microhardness in both evaluation periods, with greater absolute value without interposing barrier. The cement VariolinkTM Veneer had the lowest value of microhardness with the interposition of the barrier resin composite with measurement immediately after polymerization. The instants of measurement and type of cement affect the values of microhardness, since the filing of barriers of various materials available during the curing resin cements dual no significant influence on the microhardness values of the same.pt_BR
dc.language.isoporpt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectCimentos Dentáriospt_BR
dc.subjectTestes de Durezapt_BR
dc.subjectPorcelana Dentáriapt_BR
dc.subjectDental Cementspt_BR
dc.subjectHardness Testspt_BR
dc.subjectDental Porcelainpt_BR
dc.titleAvaliação da microdureza de três cimentos resinosos fotopolimerizados por LED com a interposição de barreiras de diferentes espessuraspt_BR
dc.title.alternativeMicrohardness evoluation of three resin cements photoactived dual with different thicknesses interposer barrierspt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor1Figueiredo, José Luiz Guimarães de-
Aparece nas coleções:Programa de Pós-graduação em Odontologia

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Juliana Maria Correia de Souza Vieira.pdf1,26 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.