Use este identificador para citar ou linkar para este item: https://repositorio.ufms.br/handle/123456789/125
Registro completo de metadados
Campo DCValorIdioma
dc.creatorBellé, Bruno Luiz Lessa-
dc.creatorLacerda, Valéria Rodrigues de-
dc.creatorDe Carli, Alessandro Diogo-
dc.creatorZafalon, Edílson José-
dc.creatorPereira, Paulo Zárate-
dc.date.accessioned2011-07-12T18:09:02Z-
dc.date.available2021-09-30T19:57:37Z-
dc.date.issued2009-
dc.identifier.citationBELLE, Bruno Luiz Lessa et al . Análise da fluoretação da água de abastecimento público da zona urbana do município de Campo Grande (MS). Ciênc. saúde coletiva, Rio de Janeiro, v. 14, n. 4, Aug. 2009 . Available from <http://www.scielosp.org/scielo.php?script=sci_arttext&pid=S1413-81232009000400032&lng=en&nrm=iso>. access on 12 July 2011. doi: 10.1590/S1413-81232009000400032.pt_BR
dc.identifier.urihttps://repositorio.ufms.br/handle/123456789/125-
dc.description.abstractO presente estudo teve por objetivo analisar a concentração de fluoreto na água que flui das torneiras da zona urbana do município de Campo Grande (MS). Para tanto, foram coletadas amostras de água de 21 escolas situadas nos sete subdistritos da cidade, em três oportunidades diferentes para análise do teor de fluoreto, determinada pelo método do eletrodo específico (medidor de fluoreto combinado Orion 9609 BN, acoplado a um potenciômetro digital EA-940 da Orion). Os resultados mostraram que 63,5% das amostras coletadas apresentaram níveis aceitáveis (entre 0,6 a 0,8 ppm) de fluoreto e 36,5%, níveis inaceitáveis. Em relação à condição dos locais de coleta, 76,2% foram consideradas adequadas e 23,8%, inadequadas.pt_BR
dc.description.abstractABSTRACT - The objective of this study was to analyze the fluoride concentration on the water that flows of the tap in the urban area of the city of Campo Grande (MS). For the fluoride concentration analysis, it was collected water samples of 21 schools placed in the 7 sub districts of the city, in 3 different opportunities, was made by the specific electrode method (using an Orion 9609 BN combined fluoride measuring electrode, coupled with an Orion EA-940 digital potentiometer). The results showed that 63.5% of the water samples presented acceptable fluoride levels (between 0.60 and 0.80 ppm) and 36.5%, unacceptable levels. In relation to the condition of the collect places, 76.2% were considered appropriate and 23.8% were inappropriate.pt_BR
dc.language.isoporpt_BR
dc.publisherCiência & Saúde Coletivapt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectFluoretospt_BR
dc.subjectFluoretaçãopt_BR
dc.subjectCárie Dentáriapt_BR
dc.subjectFluoridespt_BR
dc.subjectFluoridationpt_BR
dc.subjectDental Cariespt_BR
dc.titleAnálise da fluoretação da água de abastecimento público da zona urbana do município de Campo Grande (MS)pt_BR
dc.title.alternativeWater fluoridation analysis of Campo Grande (MS) urban zone public supplypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.doi10.1590/S1413-81232009000400032-
Aparece nas coleções:FAODO - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Analise da fluoretacao.pdf52,56 kBAdobe PDFThumbnail
Visualizar/Abrir